Insulation Between Ac Ducts In The Attic

Flexible Air Duct Replacement With Round Sheet Metal Duct Air Duct Insulation Air Duct Hvac Duct

Flexible Air Duct Replacement With Round Sheet Metal Duct Air Duct Insulation Air Duct Hvac Duct

Before After Photos Of A Bryant Furnace Air Ducts And Attic Insulation Installation In Redwood City Ca Great Job Team Hvac Installation Hvac Furnace

Before After Photos Of A Bryant Furnace Air Ducts And Attic Insulation Installation In Redwood City Ca Great Job Team Hvac Installation Hvac Furnace

Attic Remodel That Covers Hiding Air Ducts Attic Spaces Attic Remodel Attic Design

Attic Remodel That Covers Hiding Air Ducts Attic Spaces Attic Remodel Attic Design

If You Have Ducts In The Attic Use Great Stuff Insulating Foam Sealant To Seal Around All Hvac Boots Where They Penetrate Sealant Hvac Duct Home Maintenance

If You Have Ducts In The Attic Use Great Stuff Insulating Foam Sealant To Seal Around All Hvac Boots Where They Penetrate Sealant Hvac Duct Home Maintenance

Options For Installing Ductwork In Low Ceilings Attic Flooring Attic Renovation Attic Insulation

Options For Installing Ductwork In Low Ceilings Attic Flooring Attic Renovation Attic Insulation

This Illustration Shows A Several Common Attic Problems There Are Air Leaks Leaky Ducts And Low Insulation Levels Th Off Grid Living Insulation Air Leaks

This Illustration Shows A Several Common Attic Problems There Are Air Leaks Leaky Ducts And Low Insulation Levels Th Off Grid Living Insulation Air Leaks

This Illustration Shows A Several Common Attic Problems There Are Air Leaks Leaky Ducts And Low Insulation Levels Th Off Grid Living Insulation Air Leaks

So water is condensing on your ac ducts.

Insulation between ac ducts in the attic.

When water condenses and drips into your attic or home it can cause a some serious secondary problems. Flexible ductwork comes with different insulation r values. The second question gets a yes if the buried ducts meet even more stringent requirements. The duct work is insulated to keep the condensate from forming on the outside of the pipes and dripping off from the temperature differences in the attic in the summertime with ac running.

An outdoor unit which houses the fan condenser and compressor and an indoor unit which holds the evaporator and fan. First water dripping off of your ducts and onto your insulation can cause the insulation to compress which decreases it s r value or ability to insulate. So more would help. In last week s blog i discussed the practice of burying attic ducts in deep insulation since burying ducts is simply one of several ways to address the energy waste associated with the decision to locate ducts in a vented unconditioned attic it s worth taking a fresh look at all of the possible solutions to the attic duct problem.

2 duct leakage must be no higher than 1 5 cfm25 per 100 square feet of conditioned floor area. And 3 the sum of the ceiling insulation above the duct and the duct insulation must equal the prescriptive r value for ceiling insulation. 1 the air handler must be inside conditioned space. The condenser in your air conditioner works hard to get rid of heat and pressurize refrigerant for the return trip through your house.

So why put an hvac system up in the attic at all. But our erv ducts stand alone system not tied in w heat pump and 2 jumper ducts for pressure balancing from bedrooms are suspended above the insulation in our vented attic. Other times insulation may be on the outside. In more cases than not a 3 ton ac with the ducts in the attic has a ton or so of load that s just from the location of the ducts in the attic and the associated duct gains leakage etc.

Our heating and ac ducts are 100 within the thermal envelope in the floor trusses above our insulated basement. Attic hvac systems save space. Why is condensation on ductwork a problem. Because the moving air is in the ductwork for only a short period of time it does not need the insulation r value the attic floor requires.

Well mainly it s a way to save space. Most updated central air conditioned homes have a new air conditioner split system meaning the ac is broken up into parts. Put it in an attic full of blown insulation and you re. The remaining 2 tons of capacity is at least 1 5x oversized for the actual 1 load.

Table 1 shows effective r values for 8 inch round ducts at three attic insulation levels and three duct insulation levels r 4 2 r 6 and r 8. Sometimes the insulation is inside the ductwork.

8 Easy Tasks That Make Less Work For Your Ac Duct Work Hvac Duct Attic Insulation

8 Easy Tasks That Make Less Work For Your Ac Duct Work Hvac Duct Attic Insulation

How To Insulate Round Sheet Metal Air Duct Insulation Sleeve Duct Insulation Air Duct Insulation Air Duct

How To Insulate Round Sheet Metal Air Duct Insulation Sleeve Duct Insulation Air Duct Insulation Air Duct

Hvac Flexible Air Duct Branch Line Air Duct Hvac Duct Hvac

Hvac Flexible Air Duct Branch Line Air Duct Hvac Duct Hvac

Attic Insulation And Baffles Insulation Radiant And Vapor Barriers Attic Insulation Insulation Baffles Air Conditioning Logo

Attic Insulation And Baffles Insulation Radiant And Vapor Barriers Attic Insulation Insulation Baffles Air Conditioning Logo

Source : pinterest.com